[{"data":1,"prerenderedAt":30},["Reactive",2],{"topicsCategoryDetail-topics-en":3,"topics-asnite-en-undefined":10},{"name":4,"description":5,"id":6,"createdAt":7,"updatedAt":8,"publishedAt":7,"revisedAt":9},"Product Topics","Below is our selection of new and active products from a variety of product categories.","topics","2023-08-15T07:03:03.889Z","2023-10-30T02:46:13.77Z","2023-10-04T05:35:42.867Z",{"category":11,"title":12,"main_visual":13,"topics_type":17,"id":27,"createdAt":28,"updatedAt":29,"publishedAt":29,"revisedAt":29},{"name":4,"description":5,"id":6,"createdAt":7,"updatedAt":8,"publishedAt":7,"revisedAt":9},"Centrifugal Acceleration Calibration with Japan's First Accreditation",{"url":14,"height":15,"width":16},"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/b114e74a18394f7caf95325dbc8b8351/topics_asnite_keyvisual_01_en.jpg",576,1024,[18],{"fieldId":19,"description":20,"button_name":21,"button_link":22,"body":23},"detail","Our ASNITE calibration service for accelerometers  is capable of performing centrifugal acceleration calibration based on the requirements of ISO/IEC 17025. On November 6, 2020, we became the first accredited calibration laboratory in Japan for centrifugal acceleration calibration.","Accreditation of ASNITE Calibration Business","https://www.kyowa-ei.com/en/sustainability/traceability/asnite",[24],{"fieldId":25,"content":26},"rich_text","\u003Ch2 id=\"h2345cfc073\">Compliance with IATF 16949\u003C/h2>\u003Cp>We can issue calibration certificates with accreditation symbols.\u003Cbr>The inclusion of the national accreditation body mark (\u003Ca href=\"https://www.nite.go.jp/en/iajapan/aboutus/gyoumu/index.html\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">IAJapan\u003C/a> accreditation symbol) and the International Laboratory Accreditation Cooperation Mutual Recognition Arrangement mark (\u003Ca href=\"https://www.nite.go.jp/en/iajapan/aboutus/kokusai/mra.html\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">ilac-MRA\u003C/a> mark) on the calibration certificate allows for the fulfillment of requirements related to external laboratories under IATF 16949.\u003C/p>\u003Cp>IATF 16949: Quality management system requirements for automotive production and relevant service parts organizations.\u003C/p>\u003Ch2 id=\"h931b982adc\">Calibration Method\u003C/h2>\u003Cp>Centrifugal calibration according to ISO 16063-17*\u003C/p>\u003Cp>*ISO 16063-17:2016 (Methods for the calibration of vibration and shock transducers — Part 17: Primary calibration by centrifuge), a standard method for calibrating accelerometers.\u003C/p>\u003Cfigure>\u003Cimg src=\"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/928d80b8d0544441993ddab71747c0cd/topics_asnite_images_01.png?w=512&amp;h=288\" alt=\"\" width=\"512\" height=\"288\">\u003C/figure>\u003Ch2 id=\"h3f8455cfb9\">Items Subject to Calibration\u003C/h2>\u003Cul>\u003Cli>Strain gage type  acceleration transducers (Voltage ratio sensitivity, mV·s\u003Cspan class=\"rich_text-sup\">2\u003C/span>/V·m)*\u003C/li>\u003Cli>Piezoelectric acceleration transducers with built-in amplifiers (Voltage sensitivity, mV·s\u003Cspan class=\"rich_text-sup\">2\u003C/span>/m)*\u003C/li>\u003C/ul>\u003Cp>*Note: The unit of voltage ratio sensitivity or voltage sensitivity for the calibration value stated in the calibration certificate is the output voltage (mV or mV/V) of the  acceleration transducers per unit acceleration (1 m/s\u003Cspan class=\"rich_text-sup\">2\u003C/span>).\u003C/p>\u003Ch3 id=\"h7af105cbe7\">General-purpose acceleration transducers\u003C/h3>\u003Cul>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-ash-a\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">ASH-A\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-as-ga\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">AS-GA\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-as-gb\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">AS-GB\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-ama-a\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">AMA-A\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-amas-a\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">AMAS-A\u003C/a>\u003C/li>\u003C/ul>\u003Ch3 id=\"hfbdac1a0d0\">Sensors for automotive crash testing\u003C/h3>\u003Cul>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-asd-b\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">ASD-B\u003C/a>\u003C/li>\u003Cli>\u003Ca href=\"https://product.kyowa-ei.com/en/products/acceleration-transducers/type-ase-a\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">ASE-A\u003C/a>\u003C/li>\u003C/ul>\u003Cp>The range of compatible products is scheduled to expand sequentially.\u003C/p>\u003Ch2 id=\"h4543b62298\">Calibration Acceleration\u003C/h2>\u003Cp>Calibration is performed at the rated capacity of the  acceleration transducers.\u003C/p>\u003Cp>*Acceleration transducers with a rated capacity of 1961 m/s\u003Cspan class=\"rich_text-sup\">2\u003C/span> (200 G) will be calibrated at 9807 m/s\u003Cspan class=\"rich_text-sup\">2\u003C/span> (1000 G).\u003C/p>\u003Ctable>\u003Ctbody>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Rated Capacity (m/s\u003Cspan class=\"rich_text-sup\">2\u003C/span>)\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>9.807\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>19.61\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>49.03\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>98.07\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>196.1\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>490.3\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>980.7\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>1961\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>4903\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>9807\u003C/p>\u003C/th>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Reference (G)\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>1\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>2\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>5\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>10\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>20\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>50\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>100\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>200\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>500\u003C/p>\u003C/th>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>1000\u003C/p>\u003C/th>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Voltage Ratio Sensitivity \u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Voltage Sensitivity\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>●\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>-\u003C/p>\u003C/td>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>-\u003C/p>\u003C/td>\u003C/tr>\u003C/tbody>\u003C/table>\u003Ch2 id=\"hfd8c6116d1\">Items outside the scope of ASNITE accreditation\u003C/h2>\u003Cp>The calibration certificate includes physical quantity conversion values (μV/V, ×10\u003Cspan class=\"rich_text-sup\">-6\u003C/span>) as descriptions outside the scope of ASNITE accreditation.\u003Cbr>Calibration factors can be configured in our measuring instruments without any recalculation. The certificate also includes data for initial unbalance, non-linearity, hysteresis, and input/output resistance.\u003C/p>\u003Ch2 id=\"hd2d2d0c53e\">Concerning products of other brands\u003C/h2>\u003Cp>Calibration services are available for accelerometers from other manufacturers. However, some models may be declined based on their specifications. Please contact our sales office or distributor in advance for inquiries.\u003C/p>","asnite","2026-01-26T04:51:04.857Z","2026-01-26T05:13:35.393Z",1787540005668]