[{"data":1,"prerenderedAt":111},["Reactive",2],{"topicsCategoryDetail-custommade-en":3,"topics-luk-s-30mn-en-undefined":9},{"name":4,"description":5,"id":6,"createdAt":7,"updatedAt":8,"publishedAt":7,"revisedAt":8},"KYOWA's \"That product is actually available.\"","Kyowa has many products and applications that cannot be listed in our general catalog.\nOn this page, our web sales staff will introduce list of those that we particularly recommend.","custommade","2023-10-20T02:46:52.846Z","2024-01-16T06:02:13.295Z",{"category":10,"title":11,"main_visual":12,"topics_type":16,"id":108,"createdAt":109,"updatedAt":110,"publishedAt":110,"revisedAt":110},{"name":4,"description":5,"id":6,"createdAt":7,"updatedAt":8,"publishedAt":7,"revisedAt":8},"High-Capacity Tension / Compression Load Cell LUK-S-30MN",{"url":13,"height":14,"width":15},"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/553aa340f88d4f7a96268bb2c156db91/topics_luk-s-30mn_keyvisual_01_en.jpg",576,1024,[17],{"fieldId":18,"description":19,"button_name":20,"button_link":21,"body":22},"detail","High-Capacity Load Cell capable of measuring loads up to 30 MN  (approx. 3000 tf).\nThis ultra-high-capacity model achieves a rating 15 times greater than our standard maximum catalog capacity of 2 MN. \nNote: Maximum capacity of 30 MN applies to compression only. The maximum capacity for tension is 10 MN.","Leaflet","https://files.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/b36f1a31d5e844628b7d8f01e8b2ba22/topics_luk-s-30mn_leaflet_01_en.pdf",[23,48,50,53,67,68,70,71,73,79,80,82,83,90,91,93,102,103,105],{"fieldId":24,"anchor_link":25},"anchor_link",[26,30,33,36,39,42,45],{"fieldId":27,"link_name":28,"link_id":29},"anchor_link_link","Features","features",{"fieldId":27,"link_name":31,"link_id":32},"Line Up","lineup",{"fieldId":27,"link_name":34,"link_id":35},"Application","applications",{"fieldId":27,"link_name":37,"link_id":38},"Specifications Example","specifications",{"fieldId":27,"link_name":40,"link_id":41},"Dimensions","dimensions",{"fieldId":27,"link_name":43,"link_id":44},"FAQ","faq",{"fieldId":27,"link_name":46,"link_id":47},"Download","download",{"fieldId":49,"link_target_id":29},"anchor_link_target",{"fieldId":51,"content":52},"rich_text","\u003Ch2 id=\"h6de55689cc\">Features\u003C/h2>",{"fieldId":54,"title_left":55,"image_left":56,"copy_left":60,"title_right":61,"image_right":62,"copy_right":64,"link_right":65,"url_right":66},"img_2column","Achieves ultra-high capacity in a single unit.",{"url":57,"height":58,"width":59},"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/6850a6bbfb1a49df90f9d097db6d7258/topics_luk-s-30mn_features_01_en.png",486,864,"Compared to multi-unit measurement systems, this single-unit design simplifies installation while improving both safety and operational efficiency. The center features a groove and threaded holes, allowing for direct mounting to jacks and other equipment.","Custom-made available",{"url":63,"height":58,"width":59},"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/f42bbce8758e4d8aa14a06336e3eae18/topics_luk-s-30mn_features_02_en.png","Regardless of the specifications listed above, we can provide custom-made solutions tailored to your specific application and operating environment. Please feel free to contact us for a consultation! ","Contact us","/en/inquiry",{"fieldId":49,"link_target_id":32},{"fieldId":51,"content":69},"\u003Ch2 id=\"h7235ed19fd\">Line Up\u003C/h2>\u003Cfigure>\u003Cimg src=\"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/751624c738ab4465b993ad4a3b07df8b/topics_luk-s-30mn_images_01_en.jpg?w=852&amp;h=215\" alt=\"\" width=\"852\" height=\"215\">\u003C/figure>\u003Cp>Extensive experience in manufacturing high-capacity models beyond 2 MN.\u003C/p>",{"fieldId":49,"link_target_id":35},{"fieldId":51,"content":72},"\u003Ch2 id=\"hb6dbcad2cb\">Application\u003C/h2>",{"fieldId":54,"title_left":74,"image_left":75},"Compression load measurement for large-scale hydraulic equipment",{"url":76,"height":77,"width":78},"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/bc49f4f6b2ee409684e6e964be941689/topics_luk-s-30mn_applications_01.png",479,852,{"fieldId":49,"link_target_id":38},{"fieldId":51,"content":81},"\u003Ch2 id=\"h1bd38b6657\">Specifications Example\u003C/h2>\u003Ctable>\u003Ctbody>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Model name\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>LUK-S-30MN\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Rated Capacity\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Compression: 30 MN\u003Cbr>Tension: 10 MN\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Rated Output\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>2.0 mV/V±2% (at 30 MN load)\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Safe Overloads\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>150%\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Nonlinearity\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Within ±0.5% RO\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Hysteresis\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Within ±0.5% RO\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Compensated Temperature\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>-10 to 70°C\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Safe Temperature\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>-20 to 80°C\u003C/p>\u003C/td>\u003C/tr>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Weight\u003C/p>\u003C/th>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Approx. 1100 kg\u003C/p>\u003C/td>\u003C/tr>\u003C/tbody>\u003C/table>",{"fieldId":49,"link_target_id":41},{"fieldId":84,"title":40,"content":85},"accordion",[86],{"fieldId":54,"image_left":87,"caption_left":89},{"url":88,"height":77,"width":78},"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/9c7417ddf4604320b6ca54857ab37f72/topics_luk-s-30mn_dimensions_01_en.jpg","LUK-S-30MN",{"fieldId":49,"link_target_id":44},{"fieldId":51,"content":92},"\u003Ch2 id=\"h330c4af367\">FAQ\u003C/h2>",{"fieldId":84,"title":94,"content":95},"Q. Is periodic calibration available for custom-made products?",[96,99],{"fieldId":97,"paragraph":98},"p_M","A. Available\nPlease contact us via our website.",{"fieldId":100,"link_name":65,"link_url":101},"textlink_pat1_normal","/en/company/location-information#sales",{"fieldId":49,"link_target_id":47},{"fieldId":51,"content":104},"\u003Ch2 id=\"ha5548ffb0f\">Download\u003C/h2>\u003Cfigure>\u003Cimg src=\"https://images.microcms-assets.io/assets/f76ce1c9d600493d9aabe1847913815c/fde8dea2a2354c34a9a1bb09b47863d7/topics_luk-s-30mn_download_01_en.jpg\" alt=\"\" width=\"240\" height=\"340\">\u003C/figure>",{"fieldId":106,"link_name":20,"link_url":21,"login":107},"textlink_pat2_down",false,"luk-s-30mn","2026-03-26T05:00:34.725Z","2026-04-13T00:00:51.896Z",1776296870698]